Q:
A:
Q: W
A: As our parking air conditioner adopts DC electric compressor, it can work under DC12V or DC24V. That means they can be powered directly by battery of vehicles. For each type of parking air conditioner, users can choose 12V model or 24V model. Users should be very careful for choosing between 12V and 24V model because they cannot be swapped by each other.
Q: W
A: There are 3 working modes for our parking air conditioner: Eco mode, Standard Cooling Mode and Strong cooling mode. Working mode can be selected by users. The coolant capacity of 3 working modes are different. The table below shows the detail.
|
E |
S |
S |
|
|
Split Type (Box Model) 12V |
1000W (3413 BTU) |
2000W (6826 BTU) |
2800W (9556 BTU) |
|
Split Type (Box Model) 24V |
1000W (3413 BTU) |
2000W (6826 BTU) |
3000W (10239 BTU) |
|
Split Type (Backpack Model) 12V |
1000W (3413 BTU) |
2000W (6826 BTU) |
2800W (9556 BTU) |
|
Split Type (Backpack Model) 24V |
1000W (3413 BTU) |
2000W (6826 BTU) |
3000W (10239 BTU) |
|
Compact Type (Roof Mount Model) 12V |
1000W (3413 BTU) |
2000W (6826 BTU) |
2800W (9556 BTU) |
|
Compact Type (Roof Mount Model) 24V |
1000W (3413 BTU) |
2000W (6826 BTU) |
3000W (10239 BTU) |
The compressor will keep working till the ambient temperature reaches target temperature set by users or the temperature of air outlet reaches 4 degree .
Q: W
A:
|
N |
|
|
Split Type (Box Model) 12V |
800W |
|
Split Type (Box Model) 24V |
960W |
|
Split Type (Backpack Model) 12V |
800W |
|
Split Type (Backpack Model) 24V |
960W |
|
Compact Type (Roof Mount Model) 12V |
800W |
|
Compact Type (Roof Mount Model) 24V |
960W |
Q
A:
|
E |
S |
S |
|
|
Split Type (Box Model) 12V |
40A |
57A |
70A |
|
Split Type (Box Model) 24V |
12A |
27A |
42A |
|
Split Type (Backpack Model) 12V |
40A |
57A |
70A |
|
Split Type (Backpack Model) 24V |
12A |
27A |
42A |
|
Compact Type (Roof Mount Model) 12V |
40A |
57A |
70A |
|
Compact Type (Roof Mount Model) 24V |
12A |
27A |
42A |
Q
A:
Example 1: 12V/100Ah battery, strong cooling mode, compressor works in 50% of time, can sustain around 2.8h (100Ah/70A/50%=2.8) of running.
Example 2: 24V/180Ah battery, standard cooling mode, compressor works in 70% of time, can sustain around 9.5h (180Ah/27A/70%=9.5) of running.
Q
A:
|
|
|
|
|
S |
550*240*400mm 17KG |
460*160*320mm 5.5KG |
|
S |
660*490*210mm 21KG |
460*160*320mm 5.5KG |
|
C |
500*336*114mm (Indoor Part) 970*720*165mm (Outdoor Part) 35KG |
|
Q
A:
Q
A: Our parking air conditioner adopts POE68 as refrigerant oil. Sometimes when users vacuumize air conditioners, a few of refrigerant oil can possibly leak out. In this case, uses can add 20ml to 30ml refrigerant oil again. When you add refrigerant oil, you should vacuumize air conditioner firstly. Usually we add refrigerant oil before adding refrigerant.
A:
Q
A: Our parking air conditioner adopts R134a as refrigerant. For split type, 620g refrigerant should be filled in. For roof mount compact type, 600g refrigerant should be filled in.
A: The size of hole should be 600*300mm. The purpose is to fit the indoor part of air conditioner.
1. Surface cleaning of indoor unit: Wash the ceaning cloth in clean water, dry it and wipethe surface of the unit. The cloth can be dipped in the water solution of neutral ceaner.
2. The core of evaporation tank is too dirty: Remove the indoor unit casing and blow off thedust on the surface with compressed air.
3. Outdoor unit cleaning: Remove the unit casing and clean the condenser with compressedair. Avoid any bump against the condenser.
-We recommend cleaning once every month. lf there is much dust where the airconditioner is used, increase the cleaning frequency accordingly.
-Please make regular cleaning to the air conditioner to make sure it can runnormally.
4. Long time in idle: Unplug the air conditioner and wrap the outdoor unit to avoid anybump.
5. Use after long time in idle: Clean the unit body, condenser and evaporation unit; check ifthere is foreian matter at the air inlet/outlet of the indoor and outdoor unit: check if the drainpipe is clear; install batteries to the remote controller, make inspection and power it on.